The EvoApproxLibLITE is the lightweight version of our library of approximate circuits with formally guaranteed error parameters. Hardware as well as software models are provided for each circuit.

Circuit name MAE WCE MRE EP power area Download model
add8se_7A2 0.00 % 0.00 % 0.00 % 0.00 % 0.035 74.6 Verilog fileC filePython PYX
add8se_7C9 0.039 % 0.39 % 1.00 % 12.50 % 0.034 78.4 Verilog fileC filePython PYX
add8se_72D 0.14 % 0.39 % 2.88 % 62.40 % 0.030 65.7 Verilog fileC filePython PYX
add8se_7LN 0.23 % 0.59 % 4.89 % 62.50 % 0.026 59.1 Verilog fileC filePython PYX
add8se_7J7 0.41 % 1.37 % 8.19 % 84.38 % 0.021 52.6 Verilog fileC filePython PYX
add8se_7GE 0.86 % 2.73 % 15.04 % 93.36 % 0.019 43.6 Verilog fileC filePython PYX
add8se_7EB 1.78 % 5.86 % 26.88 % 96.78 % 0.014 34.7 Verilog fileC filePython PYX
add8se_7F3 3.44 % 8.79 % 82.31 % 98.44 % 0.010 26.8 Verilog fileC filePython PYX
add8se_74Q 6.56 % 17.97 % 148.60 % 99.56 % 0.0049 16.4 Verilog fileC filePython PYX
add8se_7NX 12.46 % 25.00 % 250.03 % 99.98 % 0.00037 2.3 Verilog fileC filePython PYX

Reported error parameters: MAE - Mean Absolute Error (Mean Error Magnitude), WCE - Worst-Case Absolute Error (Error Magnitude / Error Significance), MSE - Mean Squared Error, MRE - Mean Relative Error (Mean Relative Error Distance), WCRE - Worst-Case Relative Error, EP - Error Probability (Error Rate)  |  Reported design parameters: power - power consumption in mW, area - area on the chip in um2, dly - delay, all values obtained using Synopsys DC (45 nm PDK, 1 V, 25 ℃)  |  Error parameters marked by were verified using a formal technique analyzing all possible input combinations. There is a formal guarantee that the error is not worse than the shown value. The exact values are included at the beginning of each C file and Verilog file.

COMPARISON

Comparison with the complete EvoApproxLib dataset on various metrics. The first plot shows the performance wrt. the parameters used for pareto filtration. The black dots are the circuits included in this dataset. The blue dots are parameters of the circuits included in the full version of EvoApproxLib. Note that the parameters of the accurate implementation shown in the figure correspond with those exhibiting the lowest power consumption.