Circuit name MAE WCE MRE EP power area Download model
mul8s_1KV6 [1] 0.00 % 0.00 % 0.00 % 0.00 % 0.425 729.8 Verilog PDK45Verilog fileC filePython PYX
mul8s_1KV8 [1] 0.0018 % 0.0076 % 0.28 % 50.00 % 0.422 711.0 Verilog PDK45Verilog fileC filePython PYX
mul8s_1KV9 [1] 0.0064 % 0.026 % 0.90 % 68.75 % 0.410 685.2 Verilog PDK45Verilog fileC filePython PYX
mul8s_1KVA [1] 0.019 % 0.075 % 2.53 % 81.25 % 0.391 641.1 Verilog PDK45Verilog fileC filePython PYX
mul8s_1KVQ [1] 0.056 % 0.25 % 3.64 % 84.18 % 0.351 599.8 Verilog PDK45Verilog fileC filePython PYX
mul8s_1KX5 [1] 0.15 % 0.69 % 8.93 % 91.89 % 0.289 543.0 Verilog PDK45Verilog fileC filePython PYX
mul8s_1L2L [1] 0.23 % 1.16 % 12.26 % 93.16 % 0.200 411.6 Verilog PDK45Verilog fileC filePython PYX
mul8s_1L2N [1] 0.52 % 2.66 % 27.44 % 97.75 % 0.126 284.9 Verilog PDK45Verilog fileC filePython PYX
mul8s_1L12 [1] 3.08 % 12.30 % 135.77 % 98.05 % 0.052 172.2 Verilog PDK45Verilog fileC filePython PYX

Reported error parameters: MAE - Mean Absolute Error (Mean Error Magnitude), WCE - Worst-Case Absolute Error (Error Magnitude / Error Significance), MSE - Mean Squared Error, MRE - Mean Relative Error (Mean Relative Error Distance), WCRE - Worst-Case Relative Error, EP - Error Probability (Error Rate)  |  Reported design parameters: power - power consumption in mW, area - area on the chip in um2, dly - delay, all values obtained using Synopsys DC (45 nm PDK, 1 V, 25 ℃)  |  Error parameters marked by were verified using a formal technique analyzing all possible input combinations. There is a formal guarantee that the error is not worse than the shown value. The exact values are included at the beginning of each C file and Verilog file.

COMPARISON

Comparison with the complete EvoApproxLib dataset on various metrics. The first plot shows the performance wrt. the parameters used for pareto filtration. The black dots are the circuits included in this dataset. The blue dots are parameters of the circuits included in the full version of EvoApproxLib. Note that the parameters of the accurate implementation shown in the figure correspond with those exhibiting the lowest power consumption.

REFERENCES
  1. V. Mrazek, Z. Vasicek, L. Sekanina, H. Jiang and J. Han, Scalable Construction of Approximate Multipliers With Formally Guaranteed Worst Case Error in IEEE Transactions on Very Large Scale Integration (VLSI) Systems, vol. 26, no. 11, pp. 2572-2576, Nov. 2018.